ScreenOS の TFTP によるアップグレード
3CDaemon の TFTP Server にファームウェアを上げておいて、
CLI からアップデート。
ns50-1-> save software from tftp ww.xx.yy.zz ns50ns25.4.0.3r8.0 to flash
Load software from TFTP ww.xx.yy.zz (file: ns50ns25.4.0.3r8.0).
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
...
...
...
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
tftp received octets = 3397607
tftp success!
TFTP Succeeded
Save to flash. It may take a few minutes ... update new flash image (05d26a60,3397607)
platform = 14, cpu = 10, version = 16
offset = 20, address = 900000, size = 3397529
date = 0, time = 0, cksum = 408d7358
Program flash (0,3397607) ...
+++++++++++++++++++++++++done
Done
ns50-1->
ns50-1-> get system
Serial Number: xxxxxxxxxxxxxxx, Control Number: 00000000
Hardware Version: 4010(0)-(00), FPGA checksum: 00000000, VLAN1 IP (192.168.1.1)
Software Version: 4.0.3r8.0, Type: Firewall+VPN
Base Mac: 0010.dbxx.xxxx
File Name: ns50ns25.4.0., Checksum: 943df6bf
Date 08/20/2004 23:11:40, Daylight Saving Time disabled
The Network Time Protocol is Enabled
Up 0 hours 5 minutes 17 seconds Since 20 Aug 2004 23:06:23
Total Device Resets: 0
System in NAT/route mode.
Use interface IP, Config Port: 80
User Name: netscreen
以下省略
ns50-1->
ちゃんと reboot がかかっている。